The free EuroSoft® connect App allows to transmit measured values to iOS and Android smartphones or tablets via QR code or Bluetooth®.
Flue gas analyzer kit for oil and gas fuels for setting up heating systems.
The BLUELYZER® C1 Starter Set perform accurate measurments of O2, CO, draft and temperatures as well as precise calculation of various parameters such as lambda, combustion efficiency (Eta), flue gas loss (qA), dew point and CO2.
| Scope of delivery | |
| M05325002 | BLUELYZER® C1 (O2, CO, D7, Bluetooth®) |
| 500268.4 | Flue gas probe 170 mm |
| 500192 |
Condensate filter cartridge |
| 523493 | Power supply unit |
| 524697 | Charging cable |
| 521844 | Air sensor |
| 500214 | Filter set |
| 511304 | Case |
| O2 (oxygen) |
|
| Measuring range |
0 to 21.0 vol.-% |
| Accuracy |
±0.2 vol.-% RDG |
| Resolution |
0.1 vol.-% |
| Response delay (t90) |
< 30 seconds |
| CO (carbon monoxide) |
|
| Measuring range | 0 to 2,000 ppm (max. 6,000) |
| Accuracy |
±5 ppm (< 50 ppm) |
| ±5% RDG (> 50 ppm) |
|
| Resolution |
1 ppm |
| Response delay (t90) |
< 60 seconds |
| Flue gas temperature |
|
| Measuring range |
0 to 1,150 °C |
| Accuracy |
±1 °C + 1 digit (< 300 °C) |
| ±1 % RDG (> 300 °C) | |
| Resolution |
0.1 °C |
| Response delay (t90) |
< 30 seconds |
| Combustion air temperature |
|
| Measuring range |
-20 to 200 °C |
| Accuracy |
±3 °C + 1 digit (-20 < 0 °C) |
| ±1 °C + 1 digit (0 < 200 °C) | |
| Resolution |
0.1 °C |
| Response delay (t90) |
< 30 seconds |
| Draft/pressure |
|
| Measuring range |
±70 hPa (draft) |
| ±150 hPa (pressure) | |
| Accuracy | ±0.02 hPa (< 2.00 hPa) |
| ±1 % RDG (> 2.00 hPa) |
|
| Resolution |
0.01 hPa (< 20 hPa) |
| 0.1 hPa (> 20 hPa) |
|
| Max. overload | 1,350 hPa |
| Response delay (t90) | < 10 seconds |
| Option: COhigh (carbon monoxide) | |
| Measuring range | 0 to 2.0 vol.-% |
| Accuracy | ±10 ppm (< 200 ppm) |
| ±5 % RDG (> 200 ppm) | |
| Resolution | 1 ppm |
| Response delay (t90) | < 60 seconds |
| Option: NO (nitrogen oxide) | |
| Measuring range | 0 to 5,000 ppm |
| Accuracy | ±5 ppm (< 50 ppm) |
| ±5 % RDG (> 50 ppm) | |
| Resolution | 1 ppm |
| Response delay (t90) | < 60 seconds |
| Option: NOlow (nitrogen oxide low)) | |
| Measuring range | 0 to 300 ppm |
| Accuracy | ±2 ppm (< 40 ppm) |
| ±10 % RDG (> 40 ppm) | |
| Resolution | 0.1 ppm |
| Response delay (t90) | < 60 seconds |
The free EuroSoft® connect App allows to transmit measured values to iOS and Android smartphones or tablets via QR code or Bluetooth®.
The EuroSoft® connect software allows you to transmit measured values to the PC via microSD card and control the instrument remote via Bluetooth®.
Compact infrared high speed thermal printer with magnets on the rear side
Flue gas analyzer kit for all fuels to set up heating systems as well for NOx measurements (e.g. for CHPs).
Optimal for HVAC professionals for accurate adjustments or inspections of oil, gas and solid fuel heating systems.
Sensor unit for fast and reliable gas leak detection. The flexible probe makes use in areas that are difficult to access possible.
Robust and high quality flue gas analyzer set to setup oil, gas and pellets-fired heating systems.